Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option

Product Details
Customization: Available
Certification: SASO, RoHS, CB, CCC, ISO9001, CE
Compressor: Gmcc DC Inverter
Still deciding? Get samples of US$ 890/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Low MOQ
The MOQ for the supplier's products is 1
Customization from Samples
The supplier provides sample based customization services
Customization from Designs
The supplier provides design based customization services
to see all verified strength labels (8)
  • Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
  • Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
  • Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
  • Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
  • Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
  • Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Our Advantages
  • Product Parameters
  • FAQ
Overview

Basic Info.

Model NO.
KD-110C/BP
Refrigerant
R410A
Fan Motor
DC-Brushless
Master-Slave
Yes
WiFi
Yes
Transport Package
Wooden Case
Specification
11KW
Trademark
AirValley
Origin
China
HS Code
8418612090
Production Capacity
3000 Units/Month

Packaging & Delivery

Package Size
100.00cm * 38.00cm * 90.00cm
Package Gross Weight
65.000kg

Product Description

AirValley Residential Monoblock DC Inverter EVI Air to water heat pump for heating + cooling + hot water,
GMCC DC Inverter compressor & R410A refrigerant,
Lowest working ambient temperature -35 deg C
Product Description

GMCC DC Inverter compressor

Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for OptionEnergy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option

FULL DC INVERTER TECHNOLOGY
DC Inverter compressor + DC Brushless fan motor 
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option

3 functions, 5 modes:
Heating,
Cooling,
Domestic Hot Water, 

Heating + DHW,
Cooling + DHW
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option

High energy efficiency
Heating energy efficiency level A+++ at water temperature 35 deg C
Heating energy efficiency level A++ at water temperature 55 deg C
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option

Equipped with EVI technology
Stable operation at ambient temperature -35ºC
Wide running range, from -35ºC to 43ºC
 
 
User-friendly TOUCH SCREEN Controller
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
 
Wifi function for option
Control your heat pump in your smartphone anywhere, anytime.
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option


DC brushless fan motor
The high-quality DC speed-regulating motor can intelligently adjust the air volume and air pressure according to the load conditions to ensure good ventilation, and at the same time reduce power consumption by more than 30% compared with AC motors.
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option


Water side heat exchanger
The use of high-quality tube in tube heat exchangers has a simple structure, larger pipe diameter, and is not prone to scaling. At the same time, the special thread design greatly increases the heat exchange area and improves the energy efficiency of the unit.
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option

Low Noise
With the help of Full DC Inverter technology and the sound insulation covering of the whole machine, greatly reduces the noise of the unit.
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
 
Company Profile

AirValley is a heat pump manufacturer focusing on OEM and ODM. We have excellent R&D engineers and cooperate with excellent components manufacturers to provide customers with cost-effective products, and can provide customized services according to customer requirements.

All of our current sales and R&D engineers have worked in the heat pump industry for more
than 10 years, and we can provide professional and timely products and services. We have set up a professional 15HP heat pump laboratory, and at the same time have strategic cooperation with Dan-foss China. All DC Inverter commercial units have been tested for a long time in Dan-foss local laboratory to ensure the product's ultra-high performance and strong stability.
We look forward to working with you!
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
Our Advantages

Advanced Production Line

Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
Work flow chart
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
The cooperation of Dan-foss & AirValley
The commercial DC Inverter heat pump were supported by Dan-foss, the heart of heat pump - Compressor comes from Dan-foss, and the
economizer of EVI system comes from Dan-foss too, Not only that, Dan-foss help AirValley to test commercial DC Inverter heat pumps in Dan-foss
laboratory.
Energy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
Advanced Laboratory
-35ºC 15HP heat pump performance laboratory     Dan-foss laboratory in Haiyan ChinaEnergy-Efficient 11kw R410A DC Inverter Heat Pump for Chl, Ury for Option
Ultra-low temperature laboratory, Dan-foss Enthalpy difference laboratory,
Dan-foss data monitoring center, long-term operation laboratory.
Testing temperature from -40ºC ~55ºC
Maximum heat pump can be tested up to 300kW
 
Product Parameters
FULL DC INVERTER EVI AIR TO WATER HEAT PUMP COOLING + HEATING        
Model KD-110C/BP KD-180C/BP KD-270C/BP
Horse Power 3HP 6HP 10HP
Rated condition: Inlet/outlet temperature 40°C/45°C.
Dry bulb/wet bulb temperature 7°C/6°C
Heating Capacity (KW) 11 18 27
Power Input (KW) 3.45 5.62 8.43
COPh(W/W) 3.18 3.2 3.2
Nominal condition: Outlet temperature 41°C.
Dry bulb/wet bulb temperature -12°C/-14°C
Heating Capacity (KW) 7.2 12.8 20
Power Input (KW) 3.29 5.47 8.36
COPh(W/W) 2.2 2.34 2.39
Nominal condition: Outlet temperature 50°C.
Dry bulb/wet bulb temperature -12°C/-14°C
Heating Capacity (KW) 7.8 12.7 19.4
Power Input (KW) 3.9 6.16 9.7
COPh(W/W) 2 2.06 2
Low temperature condition: Outlet temperature 41°C.
Dry bulb/wet bulb temperature -20°C/-21°C 
Heating Capacity (KW) 6.3 11.7 16.3
Power Input (KW) 3.1 5.85 7.89
COPh(W/W) 2 2 2.06
Low temperature condition: Outlet temperature 50°C.
Dry bulb/wet bulb temperature -20°C/-21°C 
Heating Capacity (KW) 6.4 11.4 16.5
Power Input (KW) 3.4 6.16 9.24
COPh(W/W) 1.88 1.85 1.78
Rated cooling: Inlet/outlet temperature 12°C/7°C.
Dry bulb/wet bulb temperature 35°C/24°C
Cooling capacity (KW) 5 10.5 14.8
Power Input (KW) 2.5 4.56 6.72
EER(W/W) 2.2 2.3 2.2
Maximum current(A) 20 30 20
Power supply 220V~/50Hz 220V~/50Hz 3N/380V~/50Hz
Working ambient temperature -35ºC~43ºC
Refrigerant/Quantity R410A/1500g R410A/2700g R410A/3000g
Pipe Size DN20 DN25 DN25
Water flow rate(m³/h) 1.5 2 3.2
Water pressure drop(kPa) 60 45 60
Noise(dB(A)) ≤62 ≤62 ≤65
Net Weight(kg) 65 140 155
Dimensions(mm) 950*350*850 950*350*1250 1000*414*1395
FAQ

Q: What is a DC inverter air source heat pump?

A: A DC Inverter air source heat pump refers to a heat pump unit that uses a DC frequency conversion control system to control the corresponding DC frequency conversion compressor, DC fan and water pump. Not only the energy saving effect is good, but also the use efficiency is very high.
 
Q: Why DC inverter heat pump?
A: 1. DC inverter heat pump is more energy-saving.
In fact, DC Inverter and fixed speed heat pumps are both energy-saving products, and the biggest difference between the two is that the working mode of DC Inverter air source heat pump is more efficient than the fixed speed heat pump. When the ambient temperature is minus 15 degrees, the working efficiency of the DC Inverter and fixed speed air source heat pumps is basically the same. And when the ambient temperature drops to minus 10 degrees, the DC Inverter air source heat pump can follow the difference in ambient temperature, automatically adjust the compressor and fan speed, and realize stepless variable speed adjustment, so that energy can be fully utilized. From this point of view, frequency conversion Air source heat pumps are more efficient.
2. The temperature is more stable.
After the water temperature reaches the set temperature, the DC inverter heat pump will not stop running like the fixed speed air source heat pump, but will run at a lower frequency to maintain the set temperature, especially when providing heating (cooling) for the family. It can control the amount of heating (cold) by changing the speed of the compressor. The fixed-frequency air source heat pump maintains the set temperature by repeatedly starting and stopping the compressor. The temperature difference fluctuates greatly, and the water temperature fluctuates, so the room temperature may be overcooled or overheated.
 
Q: How to become a AirValley partner?
A: It's very simple, just place an order with us and you are our partner.
If you want to become our local agent, you need to reach a certain order volume and then sign an agency agreement with us. For agents, we have better terms of service. for example: 
1.The best product price; 
2.Priority production arrangements; 
3.Rich product training; 
4.First-hand new product consultation; 
5.Free brochure design; 
6.More timely email reply and so on.
 
Q: What is the delivery time?
A: Sample order 35~45 days after receiving deposit; Bulk order 25~40 days after receiving deposit.
 
Q: What is the warranty time?
A: We give two years warranty time after shipping time.
During the warranty time, we can supply free spare parts if any problem casued by AirValley.

 

Air to water heat pump, Air source heat pump, Heat pump water heater, DC Inverter heat pump, Water source heat pu

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now