22kw Water Source Heat Pump for Heating + Cooling
Contact Supplier
Product Highlights
- Modular Scalability: Connect up to 16 units in parallel for max 2080kW capacity with flexible installation.
- Smart Control Options: Supports Modbus BMS integration and optional WiFi remote control via smartphone.
- High Energy Efficiency: Grade One efficiency with R410A refrigerant and high-precision electronic expansion valve.
- Robust Protection: Equipped with anti-freeze, high/low pressure, overload, and phase sequence protection.
- Versatile Applications: Suitable for villas, hotels, hospitals, factories, and swimming pools for heating and cooling.
- OEM/ODM Support: Professional customization services available with experienced R&D engineers.
- Stable Operation: Modular rotation balances running time, improving reliability and extending unit life.
Product Attributes
- Customization
- Available
- Energy Efficiency Grade
- One
- Heat Temperature
- 50-70°C
- Model NO.
- WFC-30II
- Work Environment
- Common Heat Pump
- Heat Source
- Water-source
- Heating Type
- Circulating Heat
- Application
- Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
- Certification
- CE, ISO9001, CCC, CB, RoHS, SASO
- Compressor
- Panasonic/Copeland
- Refrigerant
- R410A
- Modbus
- Yes
- Master-Slave
- Yes
- WiFi
- Option
- Transport Package
- Wooden Case
- Specification
- 22KW
- Trademark
- AirValley
- Origin
- China
- HS Code
- 8418612090
- Production Capacity
- 3000 Units/Month
- Package Size
- 100.00cm * 65.00cm * 85.00cm
- Package Gross Weight
- 145.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of 22kw Water Source Heat Pump for Heating + Cooling
Find Similar Products
Product Description
Modular design, more flexible installation
Modular rotation work
Building intelligent control to improve management reliability
Modbus is an open protocol that is widely used, especially in BMS building control systems. The unit can be connected to the BMS system through the Modbus protocol to realize remote control of multiple air cooling and heat pump modules.

Multiple protection functions
Wifi function for option

High precision electronic expansion valve
High precision electronic expansion valve: use electronic expansion valve for controlling, reach 500 steps adjustment, adjust super heat degrees accurately, achieve high efficiency operation system.

Water side heat exchanger
AirValley is a heat pump manufacturer focusing on OEM and ODM. We have excellent R&D engineers and cooperate with excellent components manufacturers to provide customers with cost-effective products, and can provide customized services according to customer requirements.
Advanced Production Line

Work flow chart

The cooperation of Dan-foss & AirValley
Advanced Laboratory
-35ºC 15HP heat pump performance laboratory Dan-foss laboratory in Haiyan China
| Water source heat pump for Cooling & Heating | |||||||||||||
| Model | / | WFC-12I | WFC-20I | WFC-12II | WFC-20II | WFC-30II | WFC-40II | WFC-50II | WFC-70II | WFC-80II | WFC-120II | WFC-160II | |
| Underground water open loop | Rated cooling capacity | KW | 11 | 17 | 11 | 17 | 24 | 34 | 48 | 68 | 80 | 120 | 160 |
| Rated input power for cooling | KW | 2.15 | 3.34 | 2.11 | 3.20 | 4.72 | 6.53 | 9.18 | 13.18 | 15.72 | 23.35 | 31.56 | |
| Rated input current for cooling | A | 9.55 | 14.84 | 3.98 | 6.04 | 8.91 | 12.33 | 17.35 | 24.91 | 29.71 | 44.12 | 59.64 | |
| Cooling performance coefficient (EER) | / | 5.12 | 5.09 | 5.22 | 5.32 | 5.09 | 5.21 | 5.23 | 5.16 | 5.09 | 5.14 | 5.07 | |
| Rated heating capacity | KW | 9.5 | 16 | 9.5 | 16 | 22 | 32 | 45 | 65 | 75 | 115 | 150 | |
| Rated input power for heating | KW | 2.59 | 4.38 | 2.59 | 4.31 | 6.09 | 8.86 | 12.33 | 18.01 | 21.01 | 32.39 | 41.78 | |
| Rated input current for heating | A | 12.33 | 20.87 | 4.89 | 8.15 | 11.52 | 16.75 | 23.30 | 34.03 | 39.71 | 61.23 | 78.97 | |
| Heating performance coefficient (COP) | / | 3.67 | 3.65 | 3.67 | 3.71 | 3.61 | 3.61 | 3.65 | 3.61 | 3.57 | 3.55 | 3.59 | |
| Application side heat exchanger water flow | M3/h | 1.89 | 2.92 | 1.89 | 2.92 | 4.13 | 5.85 | 8.26 | 11.70 | 13.76 | 20.64 | 27.52 | |
| Heat source side heat exchanger water flow | M3/h | 1.03 | 1.59 | 1.03 | 1.59 | 2.25 | 3.19 | 4.50 | 6.38 | 7.51 | 11.26 | 15.01 | |
| Power supply | 1N 220V/50Hz (Special power supply for option) |
3N 380V/50Hz(Special power supply for option) | |||||||||||
| Compressor | Type | Hermetic scroll type | |||||||||||
| Quantity | PCS | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 4 | |
| Heat source side heat exchanger | Type | Shell & coil(tube) heat exchanger | |||||||||||
| Connection size | DN | DN25 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | DN80 | |
| Application side heat exchanger | Type | Shell & coil(tube) heat exchanger | |||||||||||
| Connection size | DN | DN25 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | DN80 | |
| Protections | 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc. | ||||||||||||
| Refrigerant | Type | R410A | |||||||||||
| Quantity | KG | 2.6 | 3.3 | 2.6 | 3.3 | 4.2 | 3.3x2 | 4.2x2 | 6.6x2 | 7.6x2 | 7.6x3 | 7.6x4 | |
| Dimension | mm | 956x556x680 | 1050x840x800 | 1650x1050x1200 | 2450x1100x1200 | ||||||||
| Net weight | KG | 68 | 95 | 65 | 95 | 135 | 195 | 320 | 795 | 885 | 1180 | 1210 | |
| Gross weight | KG | 78 | 105 | 75 | 105 | 145 | 215 | 340 | 830 | 920 | 1215 | 1245 | |
| Noise | DB(A) | ≤53 | ≤55 | ≤55 | ≤55 | ≤58 | ≤58 | ≤62 | ≤65 | ≤70 | ≤75 | ≤75 | |
| Note: | |||||||||||||
| 1. Underground water open loop type cooling standard condition: application side water input/output temperature 12ºC/7ºC; source side water input/output temperature 18ºC/29ºC. Underground water open loop type heating standard condition: application side water input/output temperature 40ºC/45ºC; source side water input/output temperature 15ºC/-a. | |||||||||||||
| 2. "-a " means the water flow under cooling standard condition. | |||||||||||||
| The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret. | |||||||||||||
1.The best product price;
2.Priority production arrangements;
3.Rich product training;
4.First-hand new product consultation;
5.Free brochure design;
6.More timely email reply and so on.
During the warranty time, we can supply free spare parts if any problem casued by AirValley.
Water to water heat pump, Geothermal heat pump, Air to water heat pump, Air source heat pump, Heat pump water heater, DC Inverter heat pump, Water source heat pump
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI2331651". Items marked "" are certified.
Company Profile
AirValley is a heat pump manufacturer located in Jiaxing city, near Shanghai and Hangzhou, we focus on OEM and ODM. We have excellent R&D engineers and cooperate with excellent components manufacturers to provide customers with cost-effective products, and can provide customized services according to customer requirements.
We mainly focus on DC Inverter heat pumps, such as DC Inverter air to water heat pump for heating and cooling, DC Inverter air to water heat pump for hot water, DC Inverter swimming pool heat pump.
Also we have all kinds of on/off type air source heat pump and water source heat pump.
All of our current sales and R&D engineers have worked in the heat pump industry for more than 15 years, and we can provide professional and timely products and services.
We have professional production lines for different heat pumps, 1 production line for home use heat pump, one production line for DC Inverter heat pump, one production line for commercial heat pump and 1 production line for water tanks.
We have set up a professional 15HP heat pump laboratory, which can control the ambient temperature from -35 deg C to 52 deg C, with protection of inflammable refrigerant for R290 and R32, and at the same time have strategic cooperation with Danfoss & Hitachi China. All DC Inverter commercial units have been tested for a long time in Danfoss or Hitachi laboratory to ensure the product's ultra-high performance and strong stability.
We look forward to working with you!
About Our Factory & Business Background
- Address
- Room 402, Building 4, Runjia Commercial Plaza, No. 883 Lianxiang Road, Wuyuan Street, Haiyan County, Jiaxing City, Zhejiang Province, Jiaxing, Zhejiang, China
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: one month -
Nearest Port
- Shanghai Port; Ningbo Port
-
Minimum Order Quantity
- 1 Pc
-
Supply Chain Partners
- 3
Our Production Capability & Technical Expertise
- Main Products
- Heat Pump, Water Tank, Solar Water Heater, Chiller, Water Pumps, Clorifiers, Pvt
-
Customization Options
- Customization from Samples, Customization from Designs
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Export Year
- 1 Year
-
Main Markets
- Southeast Asia/ Mideast
-
Number of Foreign Trading Staff
- 1
-
Overseas Agent/Branch
- No
-
New Products Launched in Last year
- No
FAQ
- What are the advantages of water source heat pumps?
- 1. Renewable energy utilization. 2. High efficiency, low cost, and energy saving (reduces power consumption by >70% vs electric heating). 3. Stable operation due to stable water temperature. 4. Environmental benefits with no pollution or combustion. 5. One machine for heating, cooling, and hot water. 6. Utilizes various water sources. 7. Suitable for civil, public, and industrial applications.
- How to become an AirValley partner?
- Simply place an order to become a partner. For local agents, reach a certain order volume and sign an agency agreement. Agents enjoy benefits like best pricing, priority production, training, new product consultation, free brochure design, and timely email replies.
- What is the delivery time?
- Sample orders take 35-45 days after receiving the deposit. Bulk orders take 25-40 days after receiving the deposit.
- What is the warranty time?
- We provide a two-year warranty after shipping time. During the warranty period, we supply free spare parts for any problems caused by AirValley.
- What is the maximum cooling capacity?
- By connecting up to 16 unit modules in parallel, the maximum cooling capacity can reach as high as 2080kW.
- Is WiFi control available?
- Yes, WiFi function is available as an option, allowing you to control the heat pump via smartphone anywhere and anytime.
Send your message to this supplier
People who viewed this also viewed
-
US$1,405.00-1,479.00 / Piece
-
US$1,810.00-1,905.00 / Piece
-
US$2,315.00-2,437.00 / Piece
-
US$1,405.00-1,479.00 / Piece
-
US$4,151.00-4,369.00 / Piece
-
US$1,810.00-1,905.00 / Piece
-
US$9,636.00-10,143.00 / Piece
-
US$5,518.00-5,808.00 / Piece
-
US$2,315.00-2,437.00 / Piece
-
US$485.00-510.00 / Piece
Product Groups
- Air Source Heat Pump(Heating+Cooling)
- Swimming Pool Heat Pump
- DC Inverter Air to Water Heat Pump(Heating+Cooling+DHW)
- Residential Air Source Heat Pump Water Heater
- Air Source Heat Pump Water Heater 60 degrees Celsius
- Air Source Heat Pump Water Heater 80 degrees Celsius
- Water Source Heat Pump Water Heater 60 degrees Celsius
- Water Source Heat Pump Water Heater 80 degrees Celsius
- Water Source Heat Pump(Heating+Cooling)
- Water Tanks
Find Similar Products By Category
- Supplier Homepage
- Products
- Water Source Heat Pump(Heating+Cooling)
- 22kw Water Source Heat Pump for Heating + Cooling
Related Categories
Hot Searches
- Electric Water Heater Factories
- Gas Water Heater Factories
- Washing Machine Pump
- Water Source
- Inverter Water Heat Pump
- Two Water Heat Pump
- One Water Heat Pump
- CE Water Heat Pump
- Air Source Water Heat Pump
- Water Source Heat Pump Bulkbuy