• 20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
  • 20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
  • 20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
  • 20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
  • 20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
  • 20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump

20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump

Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Work Environment: Low-temperature Heat Pump
Samples:
US$ 1647/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump pictures & photos
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
US $1,565-1,647 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Zhejiang, China
Importers and Exporters
The supplier has import and export rights
Low MOQ
The MOQ for the supplier's products is 1
Customization from Samples
The supplier provides sample based customization services
Customization from Designs
The supplier provides design based customization services
to see all verified strength labels (8)
  • Overview
  • Product Description
  • Company Profile
  • Our Advantages
  • Product Parameters
  • FAQ
Overview

Basic Info.

Model NO.
DFC20I/BPS
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB, RoHS, SASO
Compressor
Gmcc DC Inverter
Refrigerant
R32
Fan Motor
DC-Brushless
Water Pump
DC Inverter
Master-Slave
Yes
WiFi
Yes
Transport Package
Wooden Case
Specification
20KW
Trademark
AirValley
Origin
China
HS Code
8418612090
Production Capacity
3000 Units/Month

Packaging & Delivery

Package Size
120.00cm * 55.00cm * 150.00cm
Package Gross Weight
170.000kg

Product Description

AirValley Residential Monoblock DC Inverter EVI Air to water heat pump for heating + cooling + hot water,
Mitsubishi/GMCC DC Inverter compressor & R32 refrigerant,
Lowest working ambient temperature -35 deg C
Product Description

20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation PumpDetails of Mitsubishi DC Inverter compressor
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump


FULL DC INVERTER TECHNOLOGY 
DC Inverter compressor + DC Brushless fan motor + DC Inverter circulation pump
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump

3 functions, 5 modes: 
Heating,
Cooling,
Domestic Hot Water, 

Heating + DHW,
Cooling + DHW
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump

High energy efficiency
Heating energy efficiency level A+++ at water temperature 35 deg C 
Heating energy efficiency level A++ at water temperature 55 deg C
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump

Equipped with EVI technology
Stable operation at ambient temperature -35ºC 
Wide running range, from -35ºC to 43ºC
 
Built-in hydraulic module
The integrated design is adopted, and the water system is fully configured (built-in hydraulic modules such as DC Inverter water pump and water flow switch, with expansion tank and Y-shaped filter), which can effectively reduce the installation time and space of the water system and save installation costs.
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
User-friendly Controller
Two controllers for option. 
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump


Wifi function for option
Control your heat pump in your smartphone anywhere, anytime.
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump


DC brushless motor
The high-quality DC speed-regulating motor can intelligently adjust the air volume and air pressure according to the load conditions to ensure good ventilation, and at the same time reduce power consumption by more than 30% compared with AC motors.
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump

Low Noise
With the help of Full DC Inverter technology and the sound insulation covering of the whole machine, greatly reduces the noise of the unit.
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
 
Company Profile

AirValley is a heat pump manufacturer focusing on OEM and ODM. We have excellent R&D engineers and cooperate with excellent components manufacturers to provide customers with cost-effective products, and can provide customized services according to customer requirements. 

All of our current sales and R&D engineers have worked in the heat pump industry for more 
than 10 years, and we can provide professional and timely products and services. We have set up a professional 15HP heat pump laboratory, and at the same time have strategic cooperation with Dan-foss China. All DC Inverter commercial units have been tested for a long time in Dan-foss local laboratory to ensure the product's ultra-high performance and strong stability. 
We look forward to working with you!
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
Our Advantages

Advanced Production Line

20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
Work flow chart
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
The cooperation of Dan-foss & AirValley
The commercial DC Inverter heat pump were supported by Dan-foss, the heart of heat pump - Compressor comes from Dan-foss, and the 
economizer of EVI system comes from Dan-foss too, Not only that, Dan-foss help AirValley to test commercial DC Inverter heat pumps in Dan-foss 
laboratory.
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
Advanced Laboratory
-35ºC 15HP heat pump performance laboratory     Dan-foss laboratory in Haiyan China20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
Ultra-low temperature laboratory, Dan-foss Enthalpy difference laboratory, 
Dan-foss data monitoring center, long-term operation laboratory. 
Testing temperature from -40ºC ~55ºC 
Maximum heat pump can be tested up to 300kW
 
Product Parameters
DIW32 series Full DC Inverter EVI air to water heat pump for Cooling & Heating & DHW(Monoblock type R32 Built-in water pump)
Model DFC10I/BPS DFC15I/BPS DFC16I/BPS DFC20I/BPS DFC16II/BPS DFC20II/BPS DFC27II/BPS DFC32II/BPS DFC45II/BPS
Rated heating             (A7 W45) Heating capacity kW 10.00  15.00  16.00  20.00  16.00  20.00  27.00  32.00  45.00 
Input power kW 2.81  4.36  4.55  5.70  4.55  5.68  7.65  9.12  12.86 
COP W/W 3.56  3.55  3.52  3.51  3.52  3.52  3.53  3.51  3.50 
Nominal heating                    (A-12 W41) Heating capacity kW 8.00  10.00  11.50  14.50  11.50  14.50  19.50  22.50  30.00 
Input power kW 3.48  4.48  5.11  6.02  5.11  6.02  7.86  9.34  12.45 
COP W/W 2.30  2.23  2.25  2.41  2.25  2.41  2.48  2.41  2.41 
Low temp. heating                                    (A-20 W41) Heating capacity kW 6.20  9.10  9.40  12.50  9.40  12.50  16.50  18.10  25.00 
Input power kW 3.02  4.44  4.56  6.25  4.56  6.25  7.89  9.28  12.32 
COP W/W 2.05  2.05  2.06  2.00  2.06  2.00  2.09  1.95  2.03 
Rated cooling             (A35 W7) Cooling capacity kW 12.00  14.00  15.50  19.50  15.50  19.50  25.00  32.00  40.00 
Input power kW 4.07  4.75  5.34  6.63  5.34  6.63  8.56  10.92  13.29 
EER W/W 2.95  2.95  2.90  2.94  2.90  2.94  2.92  2.93  3.01 
Power supply V/Ph/Hz 220V/1/50Hz 380V/3/50Hz
Maximum input power 
(without electric heating)
kW 5.2 5.5 6.6 10.5 6.6 10.5 12.5 14.5 18.10 
Maximum input current
(without electric heating)
A 24 25.5 30 48 12.6 20 23.5 26.5 33.50 
Maximum outlet water temp.
(without electric heating)
ºC 58ºC
Operation temp. range ºC  -35~43ºC
Fan Morot Type DC BRUSHLESS
Refrigerant Type R32
Head outside the unit m 10.1 8.3 7.8 8 7.8 8 12.4 10 10
Water flow required m3/h 1.92 2.32 2.67 3.35 2.67 3.35 4.3 5.5 6.9
Water inlet/outlet pipe DN DN32
Unit dimensions mm 1100/460/731 1200/460/1025 1100/460/1403 1200/460/1572 1350/460/1698
Net weight kg 95 100 120 155 120 155 180 195 260
Gross weight kg 105 110 130 175 130 175 200 215 280
Noise level dB(A) ≤59 ≤60 ≤58 ≤62 ≤58 ≤62 ≤63 ≤63 ≤65
Test conditions:
- Rated heating: Inlet/outlet water temperature 40ºC/45ºC. Dry bulb/wet bulb temperature 7ºC/6ºC;
- Nominal heating: water inlet/outlet temperature -/41ºC. Dry bulb/wet bulb temperature -12ºC/-14ºC;
 - Low temperature heating: water inlet/outlet temperature -/41ºC. Dry bulb/wet bulb temperature -20ºC/--;
 - Rated cooling: water inlet/outlet temperature 12ºC/7ºC. Dry bulb temperature 35ºC.                                                                                                                                                                                         
FAQ

Q: What is a DC inverter air source heat pump?

A: A DC Inverter air source heat pump refers to a heat pump unit that uses a DC frequency conversion control system to control the corresponding DC frequency conversion compressor, DC fan and water pump. Not only the energy saving effect is good, but also the use efficiency is very high.
 
Q: Why DC inverter heat pump?
A: 1. DC inverter heat pump is more energy-saving.
In fact, DC Inverter and fixed speed heat pumps are both energy-saving products, and the biggest difference between the two is that the working mode of DC Inverter air source heat pump is more efficient than the fixed speed heat pump. When the ambient temperature is minus 15 degrees, the working efficiency of the DC Inverter and fixed speed air source heat pumps is basically the same. And when the ambient temperature drops to minus 10 degrees, the DC Inverter air source heat pump can follow the difference in ambient temperature, automatically adjust the compressor and fan speed, and realize stepless variable speed adjustment, so that energy can be fully utilized. From this point of view, frequency conversion Air source heat pumps are more efficient.
2. The temperature is more stable.
After the water temperature reaches the set temperature, the DC inverter heat pump will not stop running like the fixed speed air source heat pump, but will run at a lower frequency to maintain the set temperature, especially when providing heating (cooling) for the family. It can control the amount of heating (cold) by changing the speed of the compressor. The fixed-frequency air source heat pump maintains the set temperature by repeatedly starting and stopping the compressor. The temperature difference fluctuates greatly, and the water temperature fluctuates, so the room temperature may be overcooled or overheated.
 
Q: How to become a AirValley partner?
A: It's very simple, just place an order with us and you are our partner.
If you want to become our local agent, you need to reach a certain order volume and then sign an agency agreement with us. For agents, we have better terms of service. for example: 
1.The best product price; 
2.Priority production arrangements; 
3.Rich product training; 
4.First-hand new product consultation; 
5.Free brochure design; 
6.More timely email reply and so on.
 
Q: What is the delivery time?
A: Sample order 35~45 days after receiving deposit; Bulk order 25~40 days after receiving deposit.
 
Q: What is the warranty time?
A: We give two years warranty time after shipping time.
During the warranty time, we can supply free spare parts if any problem casued by AirValley.

 

Air to water heat pump, Air source heat pump, Heat pump water heater, DC Inverter heat pump, Water source heat pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump pictures & photos
20kw 3 Monoblock DC Inverter Heat Pump Built-in DC Circulation Pump
US $1,565-1,647 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Terms of Payment
LC, T/T, D/P, Western Union