Customization: | Available |
---|---|
Energy Efficiency Grade: | One |
Heat Temperature: | 50-70°C |
Still deciding? Get samples of US$ 2000/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Modular design, more flexible installation
AirValley is a heat pump manufacturer focusing on OEM and ODM. We have excellent R&D engineers and cooperate with excellent components manufacturers to provide customers with cost-effective products, and can provide customized services according to customer requirements.
Advanced Production Line
Water source heat pump for Cooling & Heating | |||||||||||||
Model | / | WFC-12I | WFC-20I | WFC-12II | WFC-20II | WFC-30II | WFC-40II | WFC-50II | WFC-70II | WFC-80II | WFC-120II | WFC-160II | |
Underground water open loop | Rated cooling capacity | KW | 11 | 17 | 11 | 17 | 24 | 34 | 48 | 68 | 80 | 120 | 160 |
Rated input power for cooling | KW | 2.15 | 3.34 | 2.11 | 3.20 | 4.72 | 6.53 | 9.18 | 13.18 | 15.72 | 23.35 | 31.56 | |
Rated input current for cooling | A | 9.55 | 14.84 | 3.98 | 6.04 | 8.91 | 12.33 | 17.35 | 24.91 | 29.71 | 44.12 | 59.64 | |
Cooling performance coefficient (EER) | / | 5.12 | 5.09 | 5.22 | 5.32 | 5.09 | 5.21 | 5.23 | 5.16 | 5.09 | 5.14 | 5.07 | |
Rated heating capacity | KW | 9.5 | 16 | 9.5 | 16 | 22 | 32 | 45 | 65 | 75 | 115 | 150 | |
Rated input power for heating | KW | 2.59 | 4.38 | 2.59 | 4.31 | 6.09 | 8.86 | 12.33 | 18.01 | 21.01 | 32.39 | 41.78 | |
Rated input current for heating | A | 12.33 | 20.87 | 4.89 | 8.15 | 11.52 | 16.75 | 23.30 | 34.03 | 39.71 | 61.23 | 78.97 | |
Heating performance coefficient (COP) | / | 3.67 | 3.65 | 3.67 | 3.71 | 3.61 | 3.61 | 3.65 | 3.61 | 3.57 | 3.55 | 3.59 | |
Application side heat exchanger water flow | M3/h | 1.89 | 2.92 | 1.89 | 2.92 | 4.13 | 5.85 | 8.26 | 11.70 | 13.76 | 20.64 | 27.52 | |
Heat source side heat exchanger water flow | M3/h | 1.03 | 1.59 | 1.03 | 1.59 | 2.25 | 3.19 | 4.50 | 6.38 | 7.51 | 11.26 | 15.01 | |
Power supply | 1N 220V/50Hz (Special power supply for option) |
3N 380V/50Hz(Special power supply for option) | |||||||||||
Compressor | Type | Hermetic scroll type | |||||||||||
Quantity | PCS | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 4 | |
Heat source side heat exchanger | Type | Shell & coil(tube) heat exchanger | |||||||||||
Connection size | DN | DN25 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | DN80 | |
Application side heat exchanger | Type | Shell & coil(tube) heat exchanger | |||||||||||
Connection size | DN | DN25 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | DN80 | |
Protections | 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc. | ||||||||||||
Refrigerant | Type | R410A | |||||||||||
Quantity | KG | 2.6 | 3.3 | 2.6 | 3.3 | 4.2 | 3.3x2 | 4.2x2 | 6.6x2 | 7.6x2 | 7.6x3 | 7.6x4 | |
Dimension | mm | 956x556x680 | 1050x840x800 | 1650x1050x1200 | 2450x1100x1200 | ||||||||
Net weight | KG | 68 | 95 | 65 | 95 | 135 | 195 | 320 | 795 | 885 | 1180 | 1210 | |
Gross weight | KG | 78 | 105 | 75 | 105 | 145 | 215 | 340 | 830 | 920 | 1215 | 1245 | |
Noise | DB(A) | ≤53 | ≤55 | ≤55 | ≤55 | ≤58 | ≤58 | ≤62 | ≤65 | ≤70 | ≤75 | ≤75 | |
Note: | |||||||||||||
1. Underground water open loop type cooling standard condition: application side water input/output temperature 12ºC/7ºC; source side water input/output temperature 18ºC/29ºC. Underground water open loop type heating standard condition: application side water input/output temperature 40ºC/45ºC; source side water input/output temperature 15ºC/-a. | |||||||||||||
2. "-a " means the water flow under cooling standard condition. | |||||||||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret. |