Contact Supplier
Product Attributes
- Customization
- Available
- Certification
- SASO, RoHS, CB, CCC, ISO9001, CE
- Compressor
- Dan-Foss
- Model NO.
- DFC80II/BP
- Refrigerant
- R410A
- Modbus
- Yes
- Master-Slave
- Yes
- WiFi
- Option
- Transport Package
- Wooden Case
- Specification
- 80KW
- Trademark
- AirValley
- Origin
- China
- HS Code
- 8418612090
- Production Capacity
- 3000 Units/Month
- Package Size
- 135.00cm * 130.00cm * 250.00cm
- Package Gross Weight
- 610.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of 80kw Commercial DC Inverter Air to Water Heat Pump Heating + Cooling Wholesale Price
Find Similar Products
Product Description
Dan-foss DC Inverter compressor & R410A refrigerant,
Maximum water output temperature 60 deg C,
Lowest working ambient temperature -35 deg C
Details of Dan-foss DC Inverter compressor
Intelligent defrosting technology to reduce heating attenuation
Modular design, more flexible installation
Building intelligent control to improve management reliability
Modbus is an open protocol that is widely used, especially in BMS building control systems. The unit can be connected to the BMS system through the Modbus protocol to realize remote control of multiple air cooling and heat pump modules.
Wifi function for option

Top quality Sensata pressure sensor
FUJIKOJI Electronic expansion valve
AirValley is a heat pump manufacturer focusing on OEM and ODM. We have excellent R&D engineers and cooperate with excellent components manufacturers to provide customers with cost-effective products, and can provide customized services according to customer requirements.
Advanced Production Line

Work flow chart

The cooperation of Dan-foss & AirValley
Advanced Laboratory
-35ºC 15HP heat pump performance laboratory Dan-foss laboratory in Haiyan China
| CDl series EVI DC Inverter air to water heat pump for Heating & Cooling Commercial type | ||||||||
| Model | DFC45II/BP | DFC60II/BP | DFC80II/BP | DFC90II/BP | DFC160II/BP | DFC180II/BP | ||
| Rated heating | Rated heating capacity (A7 W45) |
kW | 45.00 | 60.00 | 80.00 | 90.00 | 160.00 | 180.00 |
| Rated power consumption | kW | 12.36 | 16.48 | 21.93 | 25.07 | 43.93 | 50.28 | |
| COP | W/W | 3.64 | 3.64 | 3.65 | 3.59 | 3.64 | 3.58 | |
| Floor heating | Nominal heating capacity (A-12 W35) | kW | 33.00 | 44.50 | 56.00 | 67.00 | 102.00 | 135.00 |
| Nominal power consumption | kW | 10.00 | 13.48 | 16.97 | 20.30 | 31.00 | 41.16 | |
| COP | W/W | 3.30 | 3.30 | 3.30 | 3.30 | 3.29 | 3.28 | |
| Low temp. heating capacity (A-20ºC W35 ) | kW | 26.00 | 35.00 | 44.00 | 52.00 | 80.50 | 105.00 | |
| Low temp. power consumption | kW | 9.63 | 12.92 | 16.30 | 19.33 | 29.60 | 39.18 | |
| COP | W/W | 2.70 | 2.71 | 2.70 | 2.69 | 2.72 | 2.68 | |
| Fan coil heating | Nominal heating capacity (A-12 W41) | kW | 30.00 | 40.00 | 50.00 | 60.00 | 100.00 | 120.00 |
| Nominal power consumption | kW | 11.90 | 15.69 | 19.84 | 24.19 | 39.84 | 48.19 | |
| COP | W/W | 2.52 | 2.55 | 2.52 | 2.48 | 2.51 | 2.49 | |
| Low temp. heating capacity (A-20ºC W41 ) | kW | 24.00 | 32.00 | 40.38 | 48.00 | 80.00 | 95.00 | |
| Low temp. power consumption | kW | 10.76 | 14.29 | 18.78 | 22.86 | 37.21 | 45.24 | |
| COP | W/W | 2.23 | 2.24 | 2.15 | 2.10 | 2.15 | 2.10 | |
| Radiator heating | Nominal heating capacity (A-12 W50) | kW | 25.00 | 34.00 | 42.00 | 50.00 | 83.00 | 100.00 |
| Nominal power consumption | kW | 11.47 | 15.60 | 19.72 | 22.94 | 37.73 | 45.87 | |
| COP | W/W | 2.18 | 2.18 | 2.13 | 2.18 | 2.20 | 2.18 | |
| Low temp. capacity (A-20 W50) |
kW | 22.70 | 30.00 | 38.00 | 45.00 | 72.00 | 90.00 | |
| Low temp. power consumption | kW | 11.88 | 15.71 | 19.79 | 23.56 | 37.50 | 47.12 | |
| COP | W/W | 1.91 | 1.91 | 1.92 | 1.91 | 1.92 | 1.91 | |
| Nominal cooling | Nominal cooling capacity (A35 W7) | kW | 33.00 | 43.00 | 65.00 | 70.00 | 130.00 | 140.00 |
| Nominal power consumption | kW | 11.74 | 15.30 | 23.21 | 25.93 | 46.59 | 51.85 | |
| EER | W/W | 2.81 | 2.81 | 2.80 | 2.70 | 2.79 | 2.70 | |
| Refrigerant | Type | R410A | ||||||
| Compressor | Type | EVI DC Inverter compressor | ||||||
| Driver cooling | Type | Air cooled | Air cooled | Fluorine cooled | Fluorine cooled | Fluorine cooled | Fluorine cooled | |
| Air side heat exchanger | Type | High Efficiency Hydrophilic Aluminum Foil Fin Heat Exchanger | ||||||
| Water side heat exchanger | Type | Shell & tube heat exchanger | ||||||
| Power supply | / | 380V 3N~50Hz | ||||||
| Heating operating ambient temperature range | ºC | -35~48ºC | ||||||
| Cooling operating ambient temperature range | ºC | -10~48ºC | ||||||
| Maximum input power | kW | 18 | 24 | 30 | 33 | 61 | 65 | |
| Maximum input current | A | 34 | 45 | 53 | 62 | 115 | 124 | |
| Waterproof level | / | IPX4 | ||||||
| Anti-electric shock type | / | Type I | ||||||
| Water inlet/outlet pipe | DN | DN40 | DN40 | DN65 | DN65 | DN80 | DN80 | |
| Water flow required | m³/h | 5.6 | 7.4 | 11.20 | 12.10 | 22.40 | 24.1 | |
| Water pressure drop | kPa | 43 | 45 | 45 | 50 | 52 | 55 | |
| Unit dimensions | mm | 1200*950*1950 | 1250*1200*2360 | 1250*1200*2360 | 1250*1200*2360 | 2300*1250*2360 | 2300*1250*2360 | |
| Net weight | kg | 350 | 510 | 610 | 690 | 1250 | 1350 | |
| Noise level | dB(A) | ≤66 | ≤66 | ≤70 | ≤73 | ≤76 | ≤77 | |
| Test conditions: - Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb Temperature 7°C/6°C; - Floor nominal heating: Outlet Water Temperature 35°C. Dry Bulb/Wet Bulb Temperature -12°C/-13.5°C; - Floor low temp. heating: Outlet Water Temperature 35°C. Dry Bulb/Wet Bulb Temperature -20ºC/--; - Fan coil nominal heating: outlet water temperature 41ºC. Dry bulb/wet bulb temperature -12ºC/-13.5ºC; - Fan coil low temp. heating: outlet water temperature 41ºC. Dry bulb /Wet bulb temperature -20ºC/--; - Radiator nominal heating: outlet water temperature 50ºC. Dry bulb/wet bulb temperature -12ºC/-13.5ºC; - Radiator low temp. heating capacity: outlet water temperature 50ºC. Dry Bulb/wet bulb temperature -20ºC/--; - Nominal cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C. |
||||||||
1.The best product price;
2.Priority production arrangements;
3.Rich product training;
4.First-hand new product consultation;
5.Free brochure design;
6.More timely email reply and so on.
During the warranty time, we can supply free spare parts if any problem casued by AirValley.
Air to water heat pump, Air source heat pump, Heat pump water heater, DC Inverter heat pump, Water source heat pump
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI2331651". Items marked "" are certified.
Company Profile
AirValley is a heat pump manufacturer located in Jiaxing city, near Shanghai and Hangzhou, we focus on OEM and ODM. We have excellent R&D engineers and cooperate with excellent components manufacturers to provide customers with cost-effective products, and can provide customized services according to customer requirements.
We mainly focus on DC Inverter heat pumps, such as DC Inverter air to water heat pump for heating and cooling, DC Inverter air to water heat pump for hot water, DC Inverter swimming pool heat pump.
Also we have all kinds of on/off type air source heat pump and water source heat pump.
All of our current sales and R&D engineers have worked in the heat pump industry for more than 15 years, and we can provide professional and timely products and services.
We have professional production lines for different heat pumps, 1 production line for home use heat pump, one production line for DC Inverter heat pump, one production line for commercial heat pump and 1 production line for water tanks.
We have set up a professional 15HP heat pump laboratory, which can control the ambient temperature from -35 deg C to 52 deg C, with protection of inflammable refrigerant for R290 and R32, and at the same time have strategic cooperation with Danfoss & Hitachi China. All DC Inverter commercial units have been tested for a long time in Danfoss or Hitachi laboratory to ensure the product's ultra-high performance and strong stability.
We look forward to working with you!
About Our Factory & Business Background
- Address
- Room 402, Building 4, Runjia Commercial Plaza, No. 883 Lianxiang Road, Wuyuan Street, Haiyan County, Jiaxing City, Zhejiang Province, Jiaxing, Zhejiang, China
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: one month -
Nearest Port
- Shanghai Port; Ningbo Port
-
Minimum Order Quantity
- 1 Pc
-
Supply Chain Partners
- 3
Our Production Capability & Technical Expertise
- Main Products
- Heat Pump, Water Tank, Solar Water Heater, Chiller, Water Pumps, Clorifiers, Pvt
-
Customization Options
- Customization from Samples, Customization from Designs
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Export Year
- 1 Year
-
Main Markets
- Southeast Asia/ Mideast
-
Number of Foreign Trading Staff
- 1
-
Overseas Agent/Branch
- No
-
New Products Launched in Last year
- No
Send your message to this supplier
People who viewed this also viewed
-
US$10,000.00-11,000.00 / Piece
-
US$1,995.00-2,100.00 / Piece
-
US$1,359.00-1,430.00 / Piece
-
US$2,954.00-3,109.00 / Piece
-
US$846.00-890.00 / Piece
Product Groups
- Air Source Heat Pump(Heating+Cooling)
- Swimming Pool Heat Pump
- DC Inverter Air to Water Heat Pump(Heating+Cooling+DHW)
- Residential Air Source Heat Pump Water Heater
- Air Source Heat Pump Water Heater 60 degrees Celsius
- Air Source Heat Pump Water Heater 80 degrees Celsius
- Water Source Heat Pump Water Heater 60 degrees Celsius
- Water Source Heat Pump Water Heater 80 degrees Celsius
- Water Source Heat Pump(Heating+Cooling)
- Water Tanks
Find Similar Products By Category
- Supplier Homepage
- Products
- Air Source Heat Pump(Heating+Cooling)
- DC Inverter type
- 80kw Commercial DC Inverter Air to Water Heat Pump Heating + Cooling Wholesale Price
Related Categories
Hot Searches
- Pump Controller Factories
- Electrical Pump Factories
- Heat Switch Factories
- Air Conditioner Control Factories
- Heat Conductor
- Heat Sleeve
- Heat Connector
- Heat Rated
- 30 Kw Heat Pump
- Air Conditioner Bulkbuy