• 95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
  • 95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
  • 95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
  • 95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
  • 95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
  • 95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP

95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP

Energy Efficiency Grade: One
Heat Temperature: 80-90°C
Work Environment: Common Heat Pump
Samples:
US$ 3545/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP pictures & photos
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
US $3,368-3,545 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Zhejiang, China
Importers and Exporters
The supplier has import and export rights
Low MOQ
The MOQ for the supplier's products is 1
Customization from Samples
The supplier provides sample based customization services
Customization from Designs
The supplier provides design based customization services
to see all verified strength labels (8)
  • Overview
  • Product Description
  • Company Profile
  • Our Advantages
  • Product Parameters
  • FAQ
Overview

Basic Info.

Model NO.
GRS-33IIB
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB, RoHS, SASO
Compressor
Weishans
Refrigerant
R515b
Modbus
Yes
Master-Slave
Yes
WiFi
Option
Gwp
299
Flammable
None
Transport Package
Wooden Case
Specification
33KW
Trademark
AirValley
Origin
China
HS Code
8418612090
Production Capacity
3000 Units/Month

Packaging & Delivery

Package Size
130.00cm * 105.00cm * 205.00cm
Package Gross Weight
290.000kg

Product Description

AirValley High temperature air source heat pump water heater, With R515B refrigerant with lower pressure, low GWP only 299. 
Maximum water output temperature 95 deg C
Product Description

Honey-well R515B new low GWP(only 299) refrigerant, Non-flammable, for high temperature heat pump, commercial or industry use:
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Intelligent defrosting technology to reduce heating attenuation

Air source heat pump units are prone to frosting when the air density is low and the humidity is high. The air-cooled heat pump module unit can accurately judge the defrosting timing according to the main parameters of the heating operation and the load change, so as to achieve defrosting with frost and normal heating without frost, and can perform forced manual defrosting according to the actual situation.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Modular design, more flexible installation
Unit modules of different capacity specifications can be freely combined, and a maximum of 16 units can be connected in parallel, with strong compatibility and scalability. According to the site characteristics of the installation site, the user can choose a variety of combination connection methods to realize the parallel use of 1-16 modules, and the maximum cooling capacity is as high as 2080kW, fully meeting different needs. The air source module units of the same system are started in stages and run in a balanced manner, reducing the impact of the starting current of the units on the power grid.95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Modular rotation work
According to the load conditions of the system, the unit rotates the module units that are turned on first, and distributes the running time of each module unit in a balanced manner, which greatly improves the reliability and service life of the unit.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP

Building intelligent control to improve management reliability
Modbus is an open protocol that is widely used, especially in BMS building control systems. The unit can be connected to the BMS system through the Modbus protocol to realize remote control of multiple air cooling and heat pump modules.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
 
Speciall designed Weishans brand compressor, specially tested with R515B refrigerant for two years
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP

Multiple protection functions
To ensure the safe operation of the system, a modular structure is adopted, and the units are started in stages to reduce the impact of the starting current of the units on the power grid. The unit is equipped with high and low pressure switches, antifreeze protection devices, water flow switches, overload protection devices, power supply phase sequence protection devices, etc., and is equipped with an operation control device. When a fault occurs, the controller will automatically alarm in real time.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP

Wifi function for option
Control your heat pump in your smartphone anywhere, anytime.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
High precision electronic expansion valve

High precision electronic expansion valve: use electronic expansion valve for controlling, reach 500 steps adjustment, adjust super heat degrees accurately, achieve high efficiency operation system.

95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Fin Heat Exchanger
The blue hydrophilic aluminum foil fin heat exchanger adopts cross type multi-flow path design to make the heat exchange more uniform;
the internal thread copper tube design has higher heat transfer efficiency; at the same time, the hydrophilic fins are not easy to form water droplets, Spreading into a uniform water film completely on the surface of fins, eliminates the generation of water bridges, which greatly improves the heat exchange capacity and heat exchange efficiency
between the aluminum foil and the flowing air.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Water side heat exchanger
High-efficiency shell & coil heat exchanger with both cooling and heating is adopted, with water in the tube and fluorine outside the tube. High heat exchange efficiency, small size, excellent water quality, strong antifreeze ability, stable and reliable.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
 
Company Profile

AirValley is a heat pump manufacturer focusing on OEM and ODM. We have excellent R&D engineers and cooperate with excellent components manufacturers to provide customers with cost-effective products, and can provide customized services according to customer requirements.

All of our current sales and R&D engineers have worked in the heat pump industry for more
than 10 years, and we can provide professional and timely products and services. We have set up a professional 15HP heat pump laboratory, and at the same time have strategic cooperation with Dan-foss China. All DC Inverter commercial units have been tested for a long time in Dan-foss local laboratory to ensure the product's ultra-high performance and strong stability.
We look forward to working with you!
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Our Advantages

Advanced Production Line

95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Work flow chart
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
The cooperation of Dan-foss & AirValley
The commercial DC Inverter heat pump were supported by Dan-foss, the heart of heat pump - Compressor comes from Dan-foss, and the
economizer of EVI system comes from Dan-foss too, Not only that, Dan-foss help AirValley to test commercial DC Inverter heat pumps in Dan-foss
laboratory.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Advanced Laboratory
-35ºC 15HP heat pump performance laboratory     Dan-foss laboratory in Haiyan China95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
Ultra-low temperature laboratory, Dan-foss Enthalpy difference laboratory,
Dan-foss data monitoring center, long-term operation laboratory.
Testing temperature from -40ºC ~55ºC
Maximum heat pump can be tested up to 300kW
 
Product Parameters
HeatMax series (High temperature air source heat pump water heater circulation type) R-515B                                                                         
Model GRS-15IIB GRS-20IIB GRS-24IIB GRS-33IIB GRS-40IIB GRS-48IIB GRS-65IIB GRS-95IIB GRS-130IIB GRS-260IIB GRS-390IIB
Nominal power HP 7 10 12 15 20 24 30 48 60 120 180
Rated heating capacity kW 15 20 24 33 40 48 65 95 130 260 390
Rated heating  input power kW 4.40  5.88  7.08  9.71  11.83  14.20  19.23  28.19  38.58  77.15  115.73 
Rated heating  input current A 8.36  11.18  13.45  18.44  22.49  26.98  36.54  53.56  73.29  146.59  219.88 
COP / 3.41  3.40  3.39  3.40  3.38  3.38  3.38  3.37  3.37  3.37  3.37 
Rated Cooling capacity kW 12.5  18.0  21.0  27.0  36.0  42.0  54.0  84.0  108.0  216.0  324.0 
Rated Cooling input power kW 5.0  7.1  8.3  10.8  14.3  16.7  21.3  33.3  43.2  86.4  129.6 
Rated Cooling   input current A 9.5  13.6  15.8  20.5  27.1  31.8  40.6  63.3  82.1  164.2  246.2 
EER / 2.51  2.52  2.52  2.50  2.52  2.51  2.53  2.52  2.50  2.50  2.50 
Maximum input power kW 5.28  7.06  8.50  11.65  14.20  17.04  23.08  33.83  46.29  92.58  138.87 
Maximum input current A 10.03  13.41  16.14  22.13  26.98  32.38  43.85  64.27  87.95  175.91  263.86 
Rated hot water output temp. ºC 75
Maximum hot water output temp. ºC 95
Operation temp. range ºC  -10~48ºC
Rated hot water production t60 L/H 215.0  286.7  344.0  473.0  573.3  688.0  931.7  1361.7  1863.3  3726.7  5590.0 
Power supply 3N 380V/50Hz
Compressor Type Hermetic scroll type
Start Mode Directly start(Soft start for option)
Quantity Set 1 1 1 1 2 2 2 4 4 8 12
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 2.58  3.44  4.13  5.68  6.88  8.26  11.18  16.34  22.36  44.72 67.08
Water Pressure Drop kPa <55 <57 <60 <70 <70 <72 <72 <75 <75 <85 <95
Pipe size mm DN25 DN40 DN40 DN40 DN50 DN50 DN65 DN80 DN80 DN150 DN200
Protections 1. High pressure and low pressure protection,
2. Anti-freezing protection,
3. High temperature protection,
4. Too big of the water temperature difference for outlet and inlet protection,
5. Overload protection,
6. Lack phase protection,
7. Reverse phase protection, etc..
Refrigerant Type R-515B
Throttle Type Electronic expansion valve
Noise DB(A) ≤63 ≤68 ≤68 ≤68 ≤69 ≤69 ≤70 ≤74 ≤75 ≤105 ≤105
Dimension mm 800/760/1100 1600/760/1100 1600/820/1600 1200/950/1950 2000/1000/1290 2000/1000/1290 1250/1200/2360  2300/1250/2360  2300/1250/2360 2400/2400/2350 3600/2400/2350
Net Weight kg 150 255 280 290 447 510 610 1250 1280 1990 2990
Testing conditions:
1. Application side initial water temperature: 15ºC, end temperature 75ºC, max. temperature 95ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC.
The above parameters are based on Refrigearnt R-515B, for parameters based on other refrigerant please contact us.
 
FAQ
Q: What is the advantages of Air Source Heat Pump?
A: 1. High energy saving efficiency
Direct heating by electric energy is relatively inefficient, and one kilowatt-hour of electricity can only produce one share of heat energy, which is one of the reasons for the high electricity bill when electric heating is used in winter. The working principle of the air source heat pump is slightly different. The compressor is driven by low power to absorb the low-grade heat energy in the air and convert it into high-grade heat energy, which is then used for indoor heating. Consuming 1 degree of electricity can get more than 3 parts of heat energy. Therefore, the electric energy consumed by the air source heat pump to produce the same heat is very low, and it is a very efficient energy-saving heating equipment.
2. High environmental protection and safety
When the air source heat pump is working, it only consumes electric energy and does not rely on natural gas, coal, oil and other non-renewable resources. Therefore, there will be no open flames, no pollutant emissions, and no pollution to the environment. It is highly environmentally friendly. At the same time, the power system of the air source heat pump is concentrated in the outdoor unit, and the heat is transmitted to the room through water, so that water and electricity can be separated, and the room will not be exposed to the power supply, which has good safety. Compared with other heating equipment, it can avoid fire and explosion. , poisoning, electric shock and other risks. Even if the fan coil unit is used for heating in winter, it will not bring danger indoors. The indoor pipes are full of water. If there is leakage, it will only wet the ceiling, and there will be no leakage of refrigerant from the fluorine air conditioner, which will reduce the fluoride content in the room. If it is too high, it will affect your health.
3. Low cost of use
The air source heat pump uses 1 kilowatt-hour of electricity to generate 3 parts of heat energy. Compared with air conditioning and electric heating, it can save 2/3 of the cost of use, and can save 1/2 of the cost of gas wall-hung boiler heating. Compared with central heating, it can also About 30% cheaper. If the heating area is 100 square meters, using air conditioners and electric heaters, the cost of day and night operation is at least 3,000 yuan, and the use of gas wall-hung boilers for heating is also day and night operation, and the cost is about 1,500 yuan. 500 yuan is enough. Of course, the cost cannot be compared with coal-fired heating, but it is higher than coal-fired heating in terms of energy cleanliness, cleanliness, convenience, and sanitation.
4. High heating comfort
The air source heat pump mainly uses the water system to work, and the heating end can be carried out through fan coils, floor heating and radiators. In terms of comfort, floor heating is well-deserved first. The indoor coils are evenly laid, and the temperature is evenly dissipated. High transmission, heat the feet first and then the body, so that the temperature feeling of warming the feet and cooling the roof is the most comfortable heating solution at present.
Not only that, the air source heat pump is also very comfortable when cooling in summer. Chilled water is generated by the heat pump host and circulated to the indoor fan coil for heat exchange. The indoor temperature is very constant (the inertia of water), and the outlet air temperature of the water system air conditioner is only 12°C-15°C, compared with fluoride air conditioners At a low temperature of 7°C-10°C, the air outlet is softer, the air outlet temperature is higher, the temperature fluctuation is smaller and the impact on humidity is smaller.
5. Wide range of use
Air source heat pumps use low electric energy to absorb heat in the air, and can be used as long as there is electricity, water, and air (the temperature is above -25°C), and are not affected by light and energy, and are less affected by the environment . The application of the air source heat pump to the air injection enthalpy increase technology makes the ability to adapt to the ambient temperature stronger, and it can be heated at -35°C-48°C, which can meet the use in most regions of the world.
6. Good stability
All the refrigerants used by air conditioners are fluorides, while the refrigerants used by air source heat pumps include fluorides and water. Fluorides are used in the main unit and water is used in the indoor part. In contrast, water is more inert and can last longer. The heat absorbed by the air energy heat pump can be stored in the water for a longer period of time, making the indoor temperature more constant, and reducing the frequent operation of equipment, so that it can be more energy-saving while maintaining stability.
7. Strong intelligent ability
The air source heat pump host is controlled by a microcomputer. When debugging, set the required parameter configuration, and the host will automatically adjust the amount of water replenishment, heating, power-off protection, water tank insulation and Heating and other work do not require complex operation control panels, and the air source heat pump can be connected to the smart 485 interface, and the air source heat pump system is compatible with the intelligent equipment of the whole house to realize remote intelligent control.
8. Long service life
The service life of gas water heaters is about 8 years, and the service life of gas wall-hung boilers can reach 15 years, but the gas quality and water quality must be good, otherwise the service life of the equipment will be scrapped after a few years of use. However, the design life of the core components of the air source heat pump is more than 15 years, which can cope with the impact of power aging and scale problems. Of course, regular maintenance can also increase the service life of the equipment.
9. Simple installation conditions
Although the air source heat pump is relatively large in size, it has certain installation space requirements. However, the installation of air source heat pumps is not limited by geology, pipelines and energy supply. The normal operation of the main engine can be realized in places with air circulation, and there is no excessive demand for power equipment, which is equivalent to the power distribution of ordinary air conditioners. Don't worry The troubles caused by insufficient power at home and capacity expansion can be used in large and small houses.
 
Q: How to become a AirValley partner?
A: It's very simple, just place an order with us and you are our partner.
If you want to become our local agent, you need to reach a certain order volume and then sign an agency agreement with us. For agents, we have better terms of service. for example: 
1.The best product price; 
2.Priority production arrangements; 
3.Rich product training; 
4.First-hand new product consultation; 
5.Free brochure design; 
6.More timely email reply and so on.
 
Q: What is the delivery time?
A: Sample order 35~45 days after receiving deposit; Bulk order 25~40 days after receiving deposit.
 
Q: What is the warranty time?
A: We give two years warranty time after shipping time.
During the warranty time, we can supply free spare parts if any problem casued by AirValley.

 

Air to water heat pump, Air source heat pump, Heat pump water heater, DC Inverter heat pump, Water source heat pump, High temperature heat pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP pictures & photos
95º C Hot Water R515b Air Source Heat Pump High Efficiency ERP
US $3,368-3,545 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Terms of Payment
LC, T/T, D/P, Western Union